SALIENT SPECIFICATIONS
INPUT
230V ±10%, 50 Hz, 3f, 5 Wire
OUTPUTS
Heater |
6.3V RMS @ 1.6 A |
Focus (WRT Cathode) |
-900 V (Beam Off) |
|
-5 to -50V (Beam On) |
Rise/Fall Time |
15 nano secs |
Throughput Delay |
75 nano secs |
Cathode (WRT Helix) |
-9.8 KV |
Collector 1 (WRT Cathode) |
45% Of Cathode Voltage @ 70 mA |
Collector 2 (WRT Cathode) |
25% Of Cathode Voltage @ 110 mA |
Helix |
Ground; Current 10 m |
PROTECTIONS
- 3 Minutes Heater Warm-up
- Helix Over voltage, Over current
- Thermal Overload: TWT & Power Conditioner
- TWT Arcs
- External Overload ETC.
MONITORS
- Status & Fault Outputs
- Helix Voltage & Current
MECHANICAL
- Dimensions : 390 D x 228 W x 191 H mm
- Weight : < 15 Kg
- Cooling : Integral Forced Air Cooled
Environmental