TWT POWER CONDITIONER - MODEL 203-D1

FEATURES
  • Compact Size, Light Weight
  • Unique Design For Easy Maintenance
  • Fully Remote Controlled With Tell-backs
  • For Powering 300W TWT.

SALIENT SPECIFICATIONS

INPUT

  • 560 V DC, 30 V DC & 18 V DC (multi outputs from AC/DC unit)

OUTPUTS

Heater  

 6.3V DC @ 2.5 A

 Grid (WRT Cathode) 

-200Vto -300 V (Grid Off) @ 0.5 mA

 

100V to 250 (Grid On)@  5 mA

Rise/Fall Time

35 nano sec

Throughput Delay 

100 nano sec

PRF

1Hz to 50KHz

Cathode (WRT Helix) 

-6KV to -6.6KV

Collector 1(WRT Ek)

70% Of Ek @ 450 mA 

Collector 2(WRT Ek)

47% Of Ek @ 550 mA 

Helix 

 Ground; Current 30 mA

PROTECTIONS

  •  3 Minutes Heater Warm-up
  •  Heater Over/Under Voltage
  •  Helix Over voltage, Over current
  •  Thermal Overload: TWT & Power Conditioner
  •  TWT Arcs
  •  External Overload  ETC.

MONITORS

  • Status & Fault Outputs
  • Helix Voltage & Current  

MECHANICAL

  • Dimensions            : 270 D x 400 W x 211 H mm
  • Weight                   :  20 Kg Max
  • Cooling                  :  Forced Air Cooled

 

Environmental

  • JSS 55555